Basic parameters:
  • Chamber pressure pchamber : 26.11->26.11 mPa (vacuum shot)
  • Chamber temperature: 12 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3416 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.55 over 5.95 to 15.5 [ms]
  • Mean toroidal magnetic field Bt: 0.145 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: 10.3 V
  • Break down voltage: 12.2 V
  • Plasma total charge: 6.2 C
  • Ohmic heating power: 10.3 kW
  • Q edge: 13.1
  • Central electron temperature: 19.0 eV

MirnovCoils


Bolometry

Diagnostics configuration