Golem shot: 4664

2011-02-24 - 201307

Basic parameters:
  • Chamber pressure pchamber : 2.43->20.04 mPa (request: 20 mPa)
  • Chamber temperature: 9 grad C
  • CBt capacitors (23 mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 0 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5472 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.99 over 12.14 to 21.13 [ms]
  • Mean toroidal magnetic field Bt: 0.382 T
  • Mean plasma current: 3.4 kA
  • Mean Uloop: 5.0 V
  • Break down voltage: 8.9 V
  • Plasma total charge: 41.2 C
  • Ohmic heating power: 17.0 kW
  • Q edge: 10.1
  • Central electron temperature: 69.4 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and