Golem shot: 4746

2011-03-10 - 125657

Basic parameters:
  • Chamber pressure pchamber : 2.80->19.51 mPa (request: 20 mPa)
  • Chamber temperature: 50 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 200 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2075 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.21 over 2.07 to 10.28 [ms]
  • Mean toroidal magnetic field Bt: 0.140 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: 10.1 V
  • Break down voltage: 13.3 V
  • Plasma total charge: 2.9 C
  • Ohmic heating power: 14.1 kW
  • Q edge: 9.0
  • Central electron temperature: 24.1 eV

Diagnostics: (configuration)

MirnovCoils_JK

FastCameraExilim

Analysis:

SafetyFactor_JK

Thanks to the specific help and