Golem shot: 5028

2011-03-29 - 144832

Basic parameters:
  • Chamber pressure pchamber : 11.84->11.93 mPa (vacuum shot)
  • Chamber temperature: 21 grad C
  • CBt capacitors (23 mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 18123 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.18 over 8.32 to 16.5 [ms]
  • Mean toroidal magnetic field Bt: 0.114 T
  • Mean plasma current: 1.7 kA
  • Mean Uloop: 7.1 V
  • Break down voltage: 9.1 V
  • Plasma total charge: 14.5 C
  • Ohmic heating power: 12.1 kW
  • Q edge: 6.1
  • Central electron temperature: 34.6 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK