Golem shot: 5055

2011-03-31 - 170452

Basic parameters:
  • Chamber pressure pchamber : 7.71->20.35 mPa (request: 20 mPa)
  • Chamber temperature: 72 grad C
  • CBt capacitors (23 mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 300 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 13503 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.03 over 4.62 to 13.65 [ms]
  • Mean toroidal magnetic field Bt: 0.093 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: 5.2 V
  • Break down voltage: 10.3 V
  • Plasma total charge: 3.5 C
  • Ohmic heating power: 4.2 kW
  • Q edge: 10.5
  • Central electron temperature: 25.8 eV

DASs:

NI
New diagnostics: (configuration)
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and