Golem shot: 5092

2011-03-31 - 210631

Basic parameters:
  • Chamber pressure pchamber : 8.65->27.03 mPa (request: 25 mPa)
  • Chamber temperature: 32 grad C
  • CBt capacitors (23 mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 75 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 100 V, triggered 1,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 28034 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.37 over 8.09 to 15.46 [ms]
  • Mean toroidal magnetic field Bt: 0.179 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: 11.2 V
  • Break down voltage: 11.5 V
  • Plasma total charge: 16.8 C
  • Ohmic heating power: 23.5 kW
  • Q edge: 7.7
  • Central electron temperature: 29.4 eV

DASs:

NI
New diagnostics: (configuration)

FastCameraExilim

Bolometry
Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and