Golem shot: 5173

2011-04-05 - 122411

previous shot next shot

Basic parameters:
  • Chamber pressure pchamber : 5.56->21.80 mPa (request: 20 mPa)
  • Chamber temperature: 29 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 000 V, triggered 1,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 000 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11810 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.36 over 14.6 to 21.96 [ms]
  • Mean toroidal magnetic field Bt: 0.253 T
  • Mean plasma current: 3.8 kA
  • Mean Uloop: 6.6 V
  • Break down voltage: 9.8 V
  • Plasma total charge: 55.1 C
  • Ohmic heating power: 25.1 kW
  • Q edge: 6.0
  • Central electron temperature: 62.1 eV

Diagnostics: (configuration)

MagnOveral

MirnovCoils_JK

Analysis:

SafetyFactor_JK

Thanks to the specific help and