Comment: Parametr A se zvýšeným tlakem pH2=30 a Tcd=2000

Golem shot: 6379

2011-11-10 - 200906



Basic parameters:
  • Chamber pressure pchamber : 2.75->29.87 mPa (request: 30 mPa)
  • Chamber temperature: 0 grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 8344 s
Data (sampling interval Ts=100 kHz):

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

IDLAnalysis_TM

Thanks to the specific help and