Comment: SW oprava ..

Golem shot: 7130

2012-02-03 - 181534



Basic parameters:
  • Chamber pressure pchamber : 3.51->15.14 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14078 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 10.116 over 7.547 to 17.663 [ms]
  • Mean toroidal magnetic field Bt: 0.171 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 8.7 V
  • Plasma total charge: 11.6 C
  • Ohmic heating power: 10.1 kW
  • Q edge: 10.3
  • Central electron temperature: 33.1 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

FastCamera

Analysis:

Thanks to the specific help and