Comment: makefile.gp opraven na rychlou verzi ..

Golem shot: 7131

2012-02-03 - 182027



Basic parameters:
  • Chamber pressure pchamber : 3.53->15.08 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14373 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.404 over 7.247 to 17.651 [ms]
  • Mean toroidal magnetic field Bt: 0.174 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 8.9 V
  • Plasma total charge: 10.4 C
  • Ohmic heating power: 9.5 kW
  • Q edge: 11.2
  • Central electron temperature: 31.3 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

FastCamera

Analysis:

Thanks to the specific help and