Comment: dalsi pokus o grafy

Golem shot: 7135

2012-02-03 - 184807



Basic parameters:
  • Chamber pressure pchamber : 3.53->15.26 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 16033 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.378 over 6.831 to 17.209 [ms]
  • Mean toroidal magnetic field Bt: 0.171 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 8.8 V
  • Plasma total charge: 9.5 C
  • Ohmic heating power: 9.4 kW
  • Q edge: 11.0
  • Central electron temperature: 31.6 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

Thanks to the specific help and