Comment: vystrel do komory po vypeceni ..

Golem shot: 7142

2012-02-03 - 200730



Basic parameters:
  • Chamber pressure pchamber : 3.11->9.78 mPa (request: 15 mPa)
  • Chamber temperature: 170 grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 251 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.21 over 4.191 to 13.401 [ms]
  • Mean toroidal magnetic field Bt: 0.121 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 7.0 V
  • Plasma total charge: 6.2 C
  • Ohmic heating power: 7.8 kW
  • Q edge: 7.3
  • Central electron temperature: 39.2 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

IPCameraTokamakRoom

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and