Comment: 2nd serv

Golem shot: 7144

2012-02-03 - 202912



Basic parameters:
  • Chamber pressure pchamber : 3.66->15.43 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1556 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.601 over 7.374 to 16.975 [ms]
  • Mean toroidal magnetic field Bt: 0.164 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 8.3 V
  • Plasma total charge: 10.5 C
  • Ohmic heating power: 9.9 kW
  • Q edge: 10.6
  • Central electron temperature: 30.4 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

IPCameraTokamakRoom

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and