Comment: A jeste je SW zapnout ..

Golem shot: 7147

2012-02-03 - 204847



Basic parameters:
  • Chamber pressure pchamber : 3.45->15.38 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2731 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.267 over 6.943 to 16.21 [ms]
  • Mean toroidal magnetic field Bt: 0.159 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: V
  • Break down voltage: 7.5 V
  • Plasma total charge: 7.3 C
  • Ohmic heating power: 8.4 kW
  • Q edge: 13.1
  • Central electron temperature: 24.8 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

IPCameraTokamakRoom

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and