Comment: SG1 Tcd 10000 Ub 600 Ucd 400

Golem shot: 7207

2012-02-16 - 090558



Basic parameters:
  • Chamber pressure pchamber : 3.77->20.27 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 10,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 4425 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 18.147 over 7.023 to 25.17 [ms]
  • Mean toroidal magnetic field Bt: 0.144 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 7.1 V
  • Plasma total charge: 9.9 C
  • Ohmic heating power: 8.4 kW
  • Q edge: 9.3
  • Central electron temperature: 34.0 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

Analysis:

SafetyFactor_JK

Thanks to the specific help and