Comment:

Golem shot: 7252

2012-02-16 - 140948



Basic parameters:
  • Chamber pressure pchamber : 3.65->19.96 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 500 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 22655 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.505 over 7.359 to 15.864 [ms]
  • Mean toroidal magnetic field Bt: 0.107 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: V
  • Break down voltage: 8.8 V
  • Plasma total charge: 14.7 C
  • Ohmic heating power: 14.8 kW
  • Q edge: 4.8
  • Central electron temperature: 37.5 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and