Comment: SG1 Tcd 16000 Ub 600 Ucd 400

Golem shot: 7266

2012-02-16 - 150640



Basic parameters:
  • Chamber pressure pchamber : 3.44->20.12 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 16,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 26067 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 24.175 over 4.514 to 28.689 [ms]
  • Mean toroidal magnetic field Bt: 0.087 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: V
  • Break down voltage: 7.2 V
  • Plasma total charge: 5.5 C
  • Ohmic heating power: 7.2 kW
  • Q edge: 6.5
  • Central electron temperature: 30.7 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and