Comment: Diagnostics ..

Golem shot: 7276

2012-02-17 - 083917



Basic parameters:
  • Chamber pressure pchamber : 3.69->11.89 mPa (request: 15 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1837 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.508 over 7.312 to 17.82 [ms]
  • Mean toroidal magnetic field Bt: 0.149 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: V
  • Break down voltage: 6.9 V
  • Plasma total charge: 9.7 C
  • Ohmic heating power: 8.2 kW
  • Q edge: 10.3
  • Central electron temperature: 31.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Spectrograms_TO

Thanks to the specific help and