Comment: Test from Prague

Golem shot: 7277

2012-02-17 - 084645



Basic parameters:
  • Chamber pressure pchamber : 3.63->20.66 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2291 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.274 over 6.182 to 14.456 [ms]
  • Mean toroidal magnetic field Bt: 0.121 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: V
  • Break down voltage: 9.1 V
  • Plasma total charge: 5.3 C
  • Ohmic heating power: 7.1 kW
  • Q edge: 12.1
  • Central electron temperature: 21.1 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

IPCameraChamber

FastCamera

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Spectrograms_TO