Comment: Leybros-Cou etude stat3

Golem shot: 7357

2012-02-23 - 091341



Basic parameters:
  • Chamber pressure pchamber : 4.04->9.85 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1930 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.779 over 7.906 to 15.685 [ms]
  • Mean toroidal magnetic field Bt: 0.205 T
  • Mean plasma current: 2.0 kA
  • Mean Uloop: V
  • Break down voltage: 9.9 V
  • Plasma total charge: 15.8 C
  • Ohmic heating power: 18.8 kW
  • Q edge: 9.3
  • Central electron temperature: 32.0 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

Thanks to the specific help and