Comment: Groupe2-PlasmaC5bis

Golem shot: 7361

2012-02-23 - 092418



Basic parameters:
  • Chamber pressure pchamber : 3.97->12.17 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 2565 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.509 over 9.475 to 18.984 [ms]
  • Mean toroidal magnetic field Bt: 0.243 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: V
  • Break down voltage: 6.9 V
  • Plasma total charge: 10.4 C
  • Ohmic heating power: 6.8 kW
  • Q edge: 19.9
  • Central electron temperature: 28.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and