Comment: Statistika

Golem shot: 7402

2012-02-23 - 212448



Basic parameters:
  • Chamber pressure pchamber : 4.32->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3622 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.617 over 6.744 to 14.361 [ms]
  • Mean toroidal magnetic field Bt: 0.115 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 7.1 V
  • Plasma total charge: 9.2 C
  • Ohmic heating power: 8.8 kW
  • Q edge: 7.4
  • Central electron temperature: 32.9 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and