Comment: Statistika

Golem shot: 7404

2012-02-23 - 212909



Basic parameters:
  • Chamber pressure pchamber : 4.25->9.93 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3897 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.648 over 8.044 to 15.692 [ms]
  • Mean toroidal magnetic field Bt: 0.165 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: V
  • Break down voltage: 7.2 V
  • Plasma total charge: 9.7 C
  • Ohmic heating power: 7.7 kW
  • Q edge: 12.4
  • Central electron temperature: 29.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and