Comment: Pro Tomase O.

Golem shot: 7410

2012-02-23 - 215033



Basic parameters:
  • Chamber pressure pchamber : 4.00->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1100 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 5192 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 12.7 over 7.941 to 20.641 [ms]
  • Mean toroidal magnetic field Bt: 0.293 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 6.8 V
  • Plasma total charge: 8.2 C
  • Ohmic heating power: 6.4 kW
  • Q edge: 26.5
  • Central electron temperature: 26.1 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and