Comment: Po doutnavem vyboji ..

Golem shot: 7546

2012-03-08 - 223356



Basic parameters:
  • Chamber pressure pchamber : 4.94->18.70 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 31312 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.375 over 5.495 to 14.87 [ms]
  • Mean toroidal magnetic field Bt: 0.218 T
  • Mean plasma current: 0.8 kA
  • Mean Uloop: V
  • Break down voltage: 8.1 V
  • Plasma total charge: 4.6 C
  • Ohmic heating power: 5.2 kW
  • Q edge: 24.6
  • Central electron temperature: 22.2 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

RakeProbe

IPCameraChamber

FastCamera

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and