Comment: India, offline: Second Shot

Golem shot: 7558

2012-03-14 - 092838



Basic parameters:
  • Chamber pressure pchamber : 4.32->11.71 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 1288 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.917 over 7.385 to 16.302 [ms]
  • Mean toroidal magnetic field Bt: 0.180 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: V
  • Break down voltage: 7.4 V
  • Plasma total charge: 9.7 C
  • Ohmic heating power: 10.7 kW
  • Q edge: 12.5
  • Central electron temperature: 26.3 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and