Comment: Spain,Madrid: - Discharge comment

Golem shot: 7563

2012-03-14 - 100847



Basic parameters:
  • Chamber pressure pchamber : 4.07->12.12 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 3690 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.231 over 7.151 to 15.382 [ms]
  • Mean toroidal magnetic field Bt: 0.125 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: V
  • Break down voltage: 8.7 V
  • Plasma total charge: 11.6 C
  • Ohmic heating power: 12.6 kW
  • Q edge: 7.1
  • Central electron temperature: 31.0 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and