Comment: Prague test

Golem shot: 7573

2012-03-14 - 122000



Basic parameters:
  • Chamber pressure pchamber : 3.72->20.74 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11614 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.574 over 6.335 to 14.909 [ms]
  • Mean toroidal magnetic field Bt: 0.126 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 8.7 V
  • Plasma total charge: 8.8 C
  • Ohmic heating power: 11.3 kW
  • Q edge: 8.1
  • Central electron temperature: 27.9 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and