Comment: UCM, Madrid, Spain.

Golem shot: 7592

2012-03-14 - 153019



Basic parameters:
  • Chamber pressure pchamber : 3.67->20.04 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 22990 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.987 over 7.297 to 15.284 [ms]
  • Mean toroidal magnetic field Bt: 0.163 T
  • Mean plasma current: 1.8 kA
  • Mean Uloop: V
  • Break down voltage: 9.5 V
  • Plasma total charge: 13.1 C
  • Ohmic heating power: 17.3 kW
  • Q edge: 8.2
  • Central electron temperature: 29.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and