Comment: Mexico_Mexico_City

Golem shot: 7594

2012-03-14 - 154147



Basic parameters:
  • Chamber pressure pchamber : 3.70->19.51 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 23665 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.49 over 7.129 to 15.619 [ms]
  • Mean toroidal magnetic field Bt: 0.128 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: V
  • Break down voltage: 8.6 V
  • Plasma total charge: 11.5 C
  • Ohmic heating power: 12.5 kW
  • Q edge: 7.2
  • Central electron temperature: 31.2 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and