Comment: Discharge comment

Golem shot: 7595

2012-03-14 - 154405



Basic parameters:
  • Chamber pressure pchamber : 3.77->30.92 mPa (request: 30 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 23822 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.567 over 5.655 to 15.222 [ms]
  • Mean toroidal magnetic field Bt: 0.224 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 9.3 V
  • Plasma total charge: 5.5 C
  • Ohmic heating power: 8.3 kW
  • Q edge: 20.2
  • Central electron temperature: 21.9 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK