Comment: Ukraine

Golem shot: 7597

2012-03-14 - 155612



Basic parameters:
  • Chamber pressure pchamber : 3.79->30.10 mPa (request: 30 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 24520 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 10.05 over 5.372 to 15.422 [ms]
  • Mean toroidal magnetic field Bt: 0.092 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 10.1 V
  • Plasma total charge: 7.9 C
  • Ohmic heating power: 13.2 kW
  • Q edge: 5.5
  • Central electron temperature: 27.6 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and