Comment: Plasma pro Honzu

Golem shot: 7620

2012-03-15 - 154645



Basic parameters:
  • Chamber pressure pchamber : 3.62->8.42 mPa (request: 12 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9544 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.323 over 10.031 to 18.354 [ms]
  • Mean toroidal magnetic field Bt: 0.184 T
  • Mean plasma current: 2.5 kA
  • Mean Uloop: V
  • Break down voltage: 8.8 V
  • Plasma total charge: 24.7 C
  • Ohmic heating power: 16.2 kW
  • Q edge: 6.6
  • Central electron temperature: 47.5 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and