Comment: opakování bez cesia, HRX statistika 1/4,papouchy zvetsene na 40ms

Golem shot: 7634

2012-03-15 - 195809



Basic parameters:
  • Chamber pressure pchamber : 4.00->9.96 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 7644 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.641 over 7.739 to 15.38 [ms]
  • Mean toroidal magnetic field Bt: 0.239 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 7.1 V
  • Plasma total charge: 7.8 C
  • Ohmic heating power: 6.3 kW
  • Q edge: 21.6
  • Central electron temperature: 26.3 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and