Comment: Vacuum shot OK, now plasma ..

Golem shot: 7664

2012-03-21 - 085420



Basic parameters:
  • Chamber pressure pchamber : 4.43->9.44 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 700 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 450 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 666 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.996 over 6.97 to 15.966 [ms]
  • Mean toroidal magnetic field Bt: 0.156 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: V
  • Break down voltage: 7.0 V
  • Plasma total charge: 7.6 C
  • Ohmic heating power: 8.4 kW
  • Q edge: 12.8
  • Central electron temperature: 24.8 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and