Comment: Pravesh2, INDIA

Golem shot: 7672

2012-03-21 - 112930



Basic parameters:
  • Chamber pressure pchamber : 3.72->20.27 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 550 V, triggered 9,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 9991 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 16.774 over 7.367 to 24.141 [ms]
  • Mean toroidal magnetic field Bt: 0.253 T
  • Mean plasma current: 1.3 kA
  • Mean Uloop: V
  • Break down voltage: 8.7 V
  • Plasma total charge: 9.8 C
  • Ohmic heating power: 11.7 kW
  • Q edge: 17.6
  • Central electron temperature: 24.7 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and