Comment: Pravesh4, INDIA

Golem shot: 7674

2012-03-21 - 113444



Basic parameters:
  • Chamber pressure pchamber : 3.83->22.31 mPa (request: 22 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 9,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 10308 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 16.637 over 7.422 to 24.059 [ms]
  • Mean toroidal magnetic field Bt: 0.254 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 9.4 V
  • Plasma total charge: 11.2 C
  • Ohmic heating power: 14.5 kW
  • Q edge: 15.3
  • Central electron temperature: 25.9 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and