Comment: Logan 3 - p=10

Golem shot: 7683

2012-03-21 - 150358



Basic parameters:
  • Chamber pressure pchamber : 3.60->11.40 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 22842 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.209 over 7.359 to 15.568 [ms]
  • Mean toroidal magnetic field Bt: 0.126 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: V
  • Break down voltage: 8.7 V
  • Plasma total charge: 12.0 C
  • Ohmic heating power: 12.5 kW
  • Q edge: 7.1
  • Central electron temperature: 31.2 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and