Comment: Alexander Green - 2

Golem shot: 7687

2012-03-21 - 171434



Basic parameters:
  • Chamber pressure pchamber : 3.55->19.96 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 30710 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.97 over 8.004 to 17.974 [ms]
  • Mean toroidal magnetic field Bt: 0.291 T
  • Mean plasma current: 1.4 kA
  • Mean Uloop: V
  • Break down voltage: 9.0 V
  • Plasma total charge: 10.9 C
  • Ohmic heating power: 13.7 kW
  • Q edge: 18.8
  • Central electron temperature: 24.5 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and