Comment: Marco, Mxico, UNAM

Golem shot: 7775

2012-03-28 - 132026



Basic parameters:
  • Chamber pressure pchamber : 3.66->23.73 mPa (request: 30 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 600 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 500 V, triggered 1,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 11789 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.236 over 6.201 to 15.437 [ms]
  • Mean toroidal magnetic field Bt: 0.133 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: 9.2 V
  • Plasma total charge: 9.1 C
  • Ohmic heating power: 11.4 kW
  • Q edge: 8.0
  • Central electron temperature: 30.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Analysis:

SafetyFactor_JK

Thanks to the specific help and