Comment: teofil_minea_eindhoven

Golem shot: 7785

2012-03-28 - 134358



Basic parameters:
  • Chamber pressure pchamber : 3.79->20.43 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1400 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 1,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 13250 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.316 over 9.502 to 17.818 [ms]
  • Mean toroidal magnetic field Bt: 0.314 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: V
  • Break down voltage: 9.9 V
  • Plasma total charge: 17.6 C
  • Ohmic heating power: 17.3 kW
  • Q edge: 14.9
  • Central electron temperature: 31.6 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and