Comment: Kharkiv, Ukraine

Golem shot: 7792

2012-03-28 - 140403



Basic parameters:
  • Chamber pressure pchamber : 3.85->24.00 mPa (request: 24 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 0,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14419 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.615 over 9.022 to 16.637 [ms]
  • Mean toroidal magnetic field Bt: 0.170 T
  • Mean plasma current: 2.5 kA
  • Mean Uloop: V
  • Break down voltage: 9.9 V
  • Plasma total charge: 22.6 C
  • Ohmic heating power: 21.2 kW
  • Q edge: 6.1
  • Central electron temperature: 39.7 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and