Comment: Kharkiv, Ukraine

Golem shot: 7793

2012-03-28 - 140633



Basic parameters:
  • Chamber pressure pchamber : 3.79->24.00 mPa (request: 24 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 0,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14578 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.563 over 9.742 to 17.305 [ms]
  • Mean toroidal magnetic field Bt: 0.214 T
  • Mean plasma current: 2.3 kA
  • Mean Uloop: V
  • Break down voltage: -10.2 V
  • Plasma total charge: 22.2 C
  • Ohmic heating power: 19.8 kW
  • Q edge: 8.4
  • Central electron temperature: 37.3 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and