Comment: Pravesh11, INDIA

Golem shot: 7800

2012-03-28 - 142554



Basic parameters:
  • Chamber pressure pchamber : 3.85->17.59 mPa (request: 16 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1100 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 8,5 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 15745 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 15.351 over 9.011 to 24.362 [ms]
  • Mean toroidal magnetic field Bt: 0.280 T
  • Mean plasma current: 2.1 kA
  • Mean Uloop: V
  • Break down voltage: 8.6 V
  • Plasma total charge: 18.8 C
  • Ohmic heating power: 18.7 kW
  • Q edge: 12.0
  • Central electron temperature: 34.3 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and