Comment: Budapest, Hungary 5

Golem shot: 7804

2012-03-28 - 150855



Basic parameters:
  • Chamber pressure pchamber : 3.63->15.38 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 18283 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 11.937 over 4.498 to 16.435 [ms]
  • Mean toroidal magnetic field Bt: 0.052 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: V
  • Break down voltage: 9.5 V
  • Plasma total charge: 8.3 C
  • Ohmic heating power: 16.5 kW
  • Q edge: 2.5
  • Central electron temperature: 32.6 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and