Comment: Budapest, Hungary 7

Golem shot: 7806

2012-03-28 - 152219



Basic parameters:
  • Chamber pressure pchamber : 3.67->21.89 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 200 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 0 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 19087 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 12.148 over 4.734 to 16.882 [ms]
  • Mean toroidal magnetic field Bt: 0.053 T
  • Mean plasma current: 1.9 kA
  • Mean Uloop: V
  • Break down voltage: 10.1 V
  • Plasma total charge: 8.8 C
  • Ohmic heating power: 17.5 kW
  • Q edge: 2.5
  • Central electron temperature: 31.4 eV

DAS:

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

Analysis:

SafetyFactor_JK

Thanks to the specific help and