Comment: Proveden doutnavy vyboj a zapojena HXR sonda

Golem shot: 7814

2012-03-29 - 164200



Basic parameters:
  • Chamber pressure pchamber : 3.44->6.81 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 8,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 14189 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 9.497 over 12.249 to 21.746 [ms]
  • Mean toroidal magnetic field Bt: 0.198 T
  • Mean plasma current: 2.5 kA
  • Mean Uloop: V
  • Break down voltage: 7.1 V
  • Plasma total charge: 30.5 C
  • Ohmic heating power: 11.0 kW
  • Q edge: 7.2
  • Central electron temperature: 61.6 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and