Comment: Upravene skripty fotodiod

Golem shot: 7818

2012-03-29 - 171519



Basic parameters:
  • Chamber pressure pchamber : 3.53->19.89 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 8,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 16199 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 8.727 over 7.237 to 15.964 [ms]
  • Mean toroidal magnetic field Bt: 0.220 T
  • Mean plasma current: 1.0 kA
  • Mean Uloop: V
  • Break down voltage: 7.5 V
  • Plasma total charge: 7.2 C
  • Ohmic heating power: 6.2 kW
  • Q edge: 19.9
  • Central electron temperature: 26.6 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and