Comment: Upravene skripty fotodiod

Golem shot: 7819

2012-03-29 - 172303



Basic parameters:
  • Chamber pressure pchamber : 3.55->12.55 mPa (request: 10 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 1000 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 8,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 0,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 16663 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 7.742 over 9.716 to 17.458 [ms]
  • Mean toroidal magnetic field Bt: 0.217 T
  • Mean plasma current: 1.5 kA
  • Mean Uloop: V
  • Break down voltage: -7.8 V
  • Plasma total charge: 14.7 C
  • Ohmic heating power: 8.4 kW
  • Q edge: 13.1
  • Central electron temperature: 37.3 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and