Comment: plazma

Golem shot: 7832

2012-03-29 - 192106



Basic parameters:
  • Chamber pressure pchamber : 3.44->19.36 mPa (request: 20 mPa)
  • Chamber temperature: N/A grad C
  • CBt capacitors ( mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 00 V, triggered 8,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 350 V, triggered 5,0 ms after Bt
  • CST capacitors (2.7 mF) charged to: 00 V, triggered 0,0 ms after Bt
  • charging log: t, UB, UBD, UCD, UDS, pchamber
  • Time since session beginning: 23735 s
Data (sampling frequency f s=1 MHz):
Plasma parameters:
  • Plasma life from 14.357 over 5.606 to 19.963 [ms]
  • Mean toroidal magnetic field Bt: 0.218 T
  • Mean plasma current: 0.9 kA
  • Mean Uloop: V
  • Break down voltage: 6.6 V
  • Plasma total charge: 5.0 C
  • Ohmic heating power: 5.0 kW
  • Q edge: 21.9
  • Central electron temperature: 26.9 eV

DAS:

Papouch_St

NIturbo.ONN
Diagnostics: (configuration)

MirnovCoils_JK

Spectrometer

HXR_LK

Analysis:

SafetyFactor_JK

Thanks to the specific help and